Single-phase current generator, compact, reliable, easy to handle and use. Recommended for both home and industrial, professional users.
The generator can also be used together with the automation provided, so that it starts automatically when the connection to the network no longer has voltage. It represents the ideal equipment in case of emergency power supply of vital consumers (lighting, surveillance systems, heating, water supply, refrigerators, etc., respecting the power limit).
Powerful thermal engine of 6.5 HP, on gasoline, in four strokes, low fuel consumption and which meets the EURO5 standards in terms of environmental pollution.
Automatic Voltage Regulator (AVR) that limits voltage fluctuations produced by the alternator.
The generator control panel, intuitive and easy to use, includes most functions and controls of the generator:
- 3 in 1 digital display with display for: voltage, frequency and operating hours.
- oil pressure warning LED - signals to users when the oil level in the bathroom drops
- the thermal fuse that interrupts the voltage supply when the equipment is overloaded, thus protecting the equipment.
Wheel kit for moving short distances, if needed, and folding handle on the generator housing to reduce the size of the equipment. The handle is equipped with a rubber sponge that ensures a firm grip and a locking/unlocking pin.
Chassis built on a protective tubular metal frame and equipped with rubber pads to increase stability and reduce vibration during operation.
Easy access to the air filter for easy cleaning or replacement.
12 volt DC outlet for light applications or rectified batteries
The generator is equipped with two single-phase sockets with a protective cover.
Side protection cover for muffler.
Large capacity fuel tank with fuel gauge.
The generator is equipped with automatic shock to be able to start without any kind of human intervention, when it is connected together with the automation.

Technical data
Nominal power: 2.5 kW
Maximum power: 2.8 kW
Nominal voltage: ~ 230 V
Nominal frequency: 50 Hz
Nominal current: 10.9 A
Power factor: 1.0
Engine model: YH168FB
Engine type: Petrol engine, 4 stroke, 1 cylinder, OHV, air cooling
Nominal engine power: 6.5 HP
Nominal speed: 3000 / 3600 rpm
Cylinder capacity: 196 cm³
Oil bath capacity: 0.6 L
Oil type: SAE10W-40, 15W-40
Fuel: unleaded petrol
Fuel tank capacity: 10 l
Voltage regulation mode: AVR
Ignition system: CDI
Winding: 100% copper
Dimensions: 615 x 450 485 mm
Noise level LwA: 93 dB(A)
Degree of protection: IP23M
Starting system: E: electric
Autonomy: 8 ores
Net/gross weight: 46/49 kg

Fuel consumption
@ 100% load: 1.71 L/h
@ 75% load: 1.54 L/h
@ 50% load: 1.18 L/h

About automation:
The generator automation ensures the contactors are engaged/disengaged and the generator starts and stops accordingly when it detects a lack of mains voltage.
Automation is particularly important when the equipment is connected to the grid because it is forbidden to feed consumers from two sources that are not synchronized in frequency, plus the very high possibility of discharging the electric current into the national grid.
Automation notices the lack of voltage in the network and orders the generator to start.
After the generator starts up and stabilizes in the parameters, the automation disconnects the main network and connects the power supply from the generator (all the while the main network is monitored when the supply voltage returns to the parameters, it is ordered to stop the generator and switch back to the network).
The generator automation is equipped with the generator battery charging source so that it is always ready to start.
The automation is equipped with relays for changing the minimum and maximum voltage of the main network, for which the generator will receive the start command. There are very common cases where the network voltage varies quite a lot, and the generator will consider it unacceptable, respectively it will receive the start command. In order to avoid operation "on the generator" although the network has a relatively good voltage, the thresholds accepted by the equipment can be changed (however limited, they will have to be changed within the reasonable range). The generator start command delay time can also be changed from this relay; thus, starting is avoided when the mains voltage disappears for very short time intervals: a few seconds.
The automation box is made with great care, the power cables are ordered according to color codes, equipped with an access door provided with a key locking system, LEDs, intuitive and easy to use.
The current of the automatic contactor